Saturday 7 January 2017

Whirlpool Air conditioner Error Code E12 1 Error, E122,E123 Error, E154 Error, E162, E163 Error



Air conditioner Error Code’s
·        Check the system when error occur refer to the service manual for error codes and troubleshooting use the product after fixing error whit out solving the problem you use means it will be danger to yourself one problem after once it’s not solve that why first this problem it’s solve you can use.
Error Indicator on Led Display:
1.     E10 1 Error Commutation error between indoor sensor and outdoor sensor unit also check the connection wire between indoor and outdoor unit. Where the power cable and communication cable is crossed or not)
2.     E12 1 Error on indoor temperature sensor check the connection of the sensor
3.     E 122,E123 Error on indoor heat exchanger check the connection of the sensor
4.     E 154 Error on indoor fan motor check the connection of the connector remove foreign substance check to see if fan spins
5.     88 Display and All Led Blinks eeprom/option error
6.     E162, E163 Error eeprom/option error
7.     E422 Error Refrigerant flow blocking error check if the service valve is completely open check if there’s any blockage in the refrigerant pipe which connects indoor and outdoor unit. Check for refrigerant leak
8.     E554 Error * above led pattem is displayed when there’s error is occur on outdoor unit check the led display on outdoor unit for the details. Lack of refrigerant (for inverter modal only) check if sufficient amount of additional refrigerant was charged for the pipe length that exceeds 7.5m. Check for refrigerant leak between valve and pipe connection
9.     Smart install mode will take approximately 7 – 13 minutes. (Actual may be different depending on the model.)
10.  When installing is successful smart install mode will end with ringing sound and the air conditioner will be in standby status (error message will not be displayed on the indoor unit indicator and the remote controller and buttons on the indoor unit will work normally.)
11.  When installation is not successful : smart install mode will end error message will be displayed on the indoor unit display
12.  Smart Install mode in progress
T88 Display Progress will be displayed from 0-99
T LED display: Indicator on the indoor unit display will blink in sequence and then all indicators will blink (this will be repeated.)   